DocumentCode :
2918000
Title :
A Heat Energy Assessment Method of the Plant Secondary Effluent as Cold and Heat Sources for Heat Pump
Author :
Zhao-yi, Zhuang ; Cheng-hu, Zang ; Qiong, Sun ; De-xing, Sun
Author_Institution :
Sch. of Municipal & Environ. Eng., Harbin Inst. of Technol., Harbin, China
fYear :
2011
fDate :
19-20 Feb. 2011
Firstpage :
655
Lastpage :
659
Abstract :
The sewage plant secondary effluent is full of low cold and heat energy, drawing cold and heat energy by direct sewage source heat pump and using it can provide heating in winter and cooling in summer. This paper introduced technical solutions of the direct sewage source heat pump system, besides, it gave the evaluating method of sewage effluent cold and heat energy - the hourly analysis method, taking a sewage plant in Qingdao as an example and comparing it with the common engineering assessment method, the results show that this method has more engineering practicability.
Keywords :
cooling; effluents; heat pumps; heating; cold sources; cooling; direct sewage source heat pump system; heat energy assessment; heat sources; heating; sewage effluent cold; sewage plant secondary effluent; Computers; Decision support systems; Distributed control; Monitoring; cold; heat energy assessment; heat pump; heat source; secondary effluent;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Computer Distributed Control and Intelligent Environmental Monitoring (CDCIEM), 2011 International Conference on
Conference_Location :
Changsha
Print_ISBN :
978-1-61284-278-3
Electronic_ISBN :
978-0-7695-4350-5
Type :
conf
DOI :
10.1109/CDCIEM.2011.55
Filename :
5747901
Link To Document :
بازگشت