Author_Institution :
North Carolina State Univ., Raleigh, NC, USA
Abstract :
A key element in the development of smart power transmission systems over the past decade is the tremendous advancement of the Wide-Area Measurement System (WAMS) technology, also commonly referred to as the Synchrophasor technology. Sophisticated digital recording devices called Phasor Measurement Units or PMUs are currently being installed at different points in the North American grid, especially under the smart grid initiatives of the US Department of Energy, to record and communicate GPS-synchronized, high sampling rate (6-60 samples/sec), dynamic power system data. Significant research efforts have been made on techniques to useWAMS for monitoring and situational awareness of large power networks dispersed across wide geographical areas. In contrast, use of WAMS for automatic feedback control has received less attention from the research community. The objective of this paper is to bridge this gap by formulating wide-area control problems for oscillation damping, voltage control, wide-area protection, and disturbance localization. We present the main research challenges that need to be overcome to realize the benefits of wide area control in power systems. Our discussion begins with a review of the fundamental physical models of different characteristic components of a large transmission-level power grid such as synchronous generators, transmission lines, and loads, followed by a description of how these subsystem-level models can be integrated to form the overall system model. We pose ten distinct control-theoretic problems. The first two problems are on using PMU measurements from selected nodes in the system to identify such system models in different resolutions in real-time, and the remaining on how the identified models can be used for designing output-feedback based damping controllers, for understanding voltage fluctuations at different nodes of the network graph, and for detecting malicious inputs entering the system dynamics via faults or extraneous- attacks. We also propose two new control paradigms, namely a scheduling approach for appropriate controller selection based on online estimation of oscillation modes, and distributed phasor-based control using model estimation. We illustrate our ideas via representative examples, many of which are inspired by well-known power transfer paths in the US west coast grid, also referred to as the Western Electricity Coordinating Council (WECC).
Keywords :
damping; feedback; graph theory; phasor measurement; power transmission control; power transmission lines; scheduling; smart power grids; voltage control; GPS; PMU measurement; US west coast grid; WAMS technology; WECC; Western Electricity Coordinating Council; automatic feedback control; control-theoretic problem; controller selection; damping controller design; digital recording device; distributed phasor-based control; disturbance localization; dynamic power system; malicious input detection; network graph; oscillation damping; oscillation mode estimation; output-feedback; phasor measurement unit; power network monitoring; power transfer path; scheduling approach; situational awareness; smart grid; smart power transmission system; subsystem-level model; synchronous generator; synchrophasor technology; transmission line; transmission-level power grid; voltage control; voltage fluctuation; wide area control; wide-area control; wide-area measurement system technology; wide-area protection; Damping; Load modeling; Monitoring; Oscillators; Power system dynamics; Voltage control; Distributed Control; Excitation Control; FACTS; IEEE C37.118; Model Reduction; NASPInet; Network Delays; Oscillation Damping; Real-time Identification; Synchronized Phasor Measurements; Wide-Area Control;