• DocumentCode
    2918958
  • Title

    Gamma-ray irradiation and post-irradiation responses of high dose range RADFETs

  • Author

    Jaksic, A. ; Ristic, G. ; Pejovic, M. ; Mohammadzadeh, A. ; Sudre, C. ; Lane, W.

  • Author_Institution
    Nat. Microelectron. Res. Centre, Cork, Ireland
  • fYear
    2001
  • fDate
    10-14 Sept. 2001
  • Firstpage
    57
  • Lastpage
    65
  • Abstract
    Gamma-ray irradiation and post-irradiation responses have been studied for the two types of radiation sensitive p-channel MOSFETs (RADFETs) from different manufacturers. In addition to, in dosimetric applications standard, threshold voltage measurements at a single specified current, transistor I-V and charge-pumping characteristics have been monitored. This has been shown to be useful in providing a more detailed insight into processes that occur during irradiation and subsequent annealing at elevated temperature. In particular, the role of switching oxide traps (also known as "border" traps) and electron traps in studied devices has been revealed.
  • Keywords
    MOSFET; annealing; dosimeters; electron traps; gamma-ray detection; hole traps; interface states; radiation hardening (electronics); semiconductor counters; annealing; border traps; charge-pumping characteristics; dosimetric applications standard; electron traps; gamma-ray irradiation; high dose range RADFETs; post-irradiation responses; radiation sensitive p-channel MOSFETs; switching oxide traps; threshold voltage measurements; transistor I-V; Annealing; Charge pumps; Current measurement; Electron traps; MOSFETs; Manufacturing; Measurement standards; Monitoring; Threshold voltage; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Radiation and Its Effects on Components and Systems, 2001. 6th European Conference on
  • Print_ISBN
    0-7803-7313-8
  • Type

    conf

  • DOI
    10.1109/RADECS.2001.1159259
  • Filename
    1159259