• DocumentCode
    2919815
  • Title

    Bayesian optimization of perfusion and transit time estimation in PASL-MRI

  • Author

    Santos, Nuno ; Sanches, João ; Figueiredo, Patrícia

  • fYear
    2010
  • fDate
    Aug. 31 2010-Sept. 4 2010
  • Firstpage
    4284
  • Lastpage
    4287
  • Abstract
    Pulsed Arterial Spin Labeling (PASL) techniques potentially allow the absolute, non-invasive quantification of brain perfusion and arterial transit time. This can be achieved by fitting a kinetic model to the data acquired at a number of inversion time points (TI). The intrinsically low SNR of PASL data, together with the uncertainty in the model parameters, can hinder the estimation of the parameters of interest. Here, a two-compartment kinetic model is used to estimate perfusion and transit time, based on a Maximum a Posteriori (MAP) criterion. A priori information concerning the physiological variation of the multiple model parameters is used to guide the solution. Monte Carlo simulations are performed to compare the accuracy of our proposed Bayesian estimation method with a conventional Least Squares (LS) approach, using four different sets of TI points. Each set is obtained either with a uniform distribution or an optimal sampling strategy designed based on the same MAP criterion. We show that the estimation errors are minimized when our proposed Bayesian estimation method is employed in combination with an optimal set of sampling points. In conclusion, our results indicate that PASL perfusion and transit time measurements would benefit from a Bayesian approach for the optimization of both the sampling strategy and the estimation algorithm, whereby prior information on the parameters is used.
  • Keywords
    Bayes methods; Monte Carlo methods; biomedical MRI; brain; cardiovascular system; haemorheology; maximum likelihood estimation; Bayesian estimation method; Bayesian optimization; Monte Carlo simulations; PASL-MRI; arterial transit time estimation; brain perfusion; inversion time points; least squares approach; maximum a posteriori criterion; pulsed arterial spin labeling; two-compartment kinetic model; Accuracy; Bayesian methods; Data models; Estimation; Labeling; Noise level; Signal to noise ratio; Bayes Theorem; Kinetics; Magnetic Resonance Imaging; Monte Carlo Method; Spin Labels;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2010 Annual International Conference of the IEEE
  • Conference_Location
    Buenos Aires
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-4123-5
  • Type

    conf

  • DOI
    10.1109/IEMBS.2010.5626174
  • Filename
    5626174