• DocumentCode
    2920997
  • Title

    Vacuum-packaged micro fuel reformer for high thermal efficiency and low package temperature

  • Author

    Kasuga, A. ; Tanaka, S. ; Esashi, M.

  • Author_Institution
    Tohoku Univ., Sendai
  • fYear
    2008
  • fDate
    13-17 Jan. 2008
  • Firstpage
    968
  • Lastpage
    971
  • Abstract
    A fully-microfabricated wafer-level vacuum package of a micro fuel reformer was designed, fabricated and tested. For thermal insulation, a high-temperature reactor is suspended by microfabricated tubes, in which fuel and reformed gas flow, and is vacuum-packaged by anodic bonding. Conductive heat loss through air in the package was investigated by making the packaging pressure as a parameter. The measured heat loss is 1.2 W at a reforming temperature of 240degC, showing a potential to realize a micro fuel reformer with a thermal efficiency of 75%. Also, the temperature of the package outside is as low as 60degC, which is enough to install the micro fuel reformer in portable electronics.
  • Keywords
    bonding processes; reactors (electric); thermal insulation; thermal management (packaging); wafer level packaging; anodic bonding; high thermal efficiency; high-temperature reactor; low package temperature; microfuel reformer; portable electronics; reformed gas flow; temperature 240 C; thermal insulation; wafer-level vacuum package; Electron tubes; Electronic packaging thermal management; Fluid flow; Fuels; Gas insulation; Inductors; Temperature; Testing; Wafer bonding; Wafer scale integration;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Micro Electro Mechanical Systems, 2008. MEMS 2008. IEEE 21st International Conference on
  • Conference_Location
    Tucson, AZ
  • ISSN
    1084-6999
  • Print_ISBN
    978-1-4244-1792-6
  • Electronic_ISBN
    1084-6999
  • Type

    conf

  • DOI
    10.1109/MEMSYS.2008.4443819
  • Filename