Title
Estimated venous return surface and cardiac output curve precisely predicts new hemodynamics after volume change
Author
Sugimachi, Masaru ; Sunagawa, Kenji ; Uemura, Kazunori ; Kamiya, Atsunori ; Shimizu, Shuji ; Inagaki, Masashi ; Shishido, Toshiaki
Author_Institution
Nat. Cardiovascular Center Res. Inst., Suita, Japan
fYear
2010
fDate
Aug. 31 2010-Sept. 4 2010
Firstpage
5205
Lastpage
5208
Abstract
In our extended Guyton´s model, the ability of heart to pump blood is characterized by a cardiac output curve and the ability of vasculature to pool blood by a venous return surface. These intersect in a three-dimensional coordinate system at the operating right atrial pressure, left atrial pressure, and cardiac output. The baseline cardiac output curve and venous return surface and their changes after volume change would predict new hemodynamics. The invasive methods needed to precisely characterize cardiac output curve and venous return surface led us to aim at estimating cardiac output curve and venous return surface from a single hemodynamic measurement. Using the average values for two logarithmic function parameters, and for two slopes of a surface, we were able to estimate cardiac output curve and venous return surface. The estimated curve and surface predicted new hemodynamics after volume change precisely.
Keywords
blood; blood vessels; cardiology; haemodynamics; physiological models; 3D coordinate system; blood pooling; cardiac output curve; estimated venous return surface; extended Guyton model; hemodynamic measurement; hemodynamics; left atrial pressure; logarithmic function parameters; right atrial pressure; surface slope; volume change; Blood; Cardiology; Dogs; Heart; Hemodynamics; Surface fitting; Animals; Atrial Function; Blood Pressure; Blood Volume; Cardiac Output; Dogs; Models, Cardiovascular; Surface Properties; Veins;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society (EMBC), 2010 Annual International Conference of the IEEE
Conference_Location
Buenos Aires
ISSN
1557-170X
Print_ISBN
978-1-4244-4123-5
Type
conf
DOI
10.1109/IEMBS.2010.5626268