DocumentCode
2924237
Title
P3-24: Coaxial klinoorotron
Author
Kurayev, A.A. ; Sinitsyn, A.K. ; Rak, A.O. ; Yeryomka, V.D.
Author_Institution
Belarusian State Univ. of Inf. & Radioelectron., Minsk, Belarus
fYear
2010
fDate
18-20 May 2010
Firstpage
377
Lastpage
378
Abstract
The coaxial klinoorotron with inhomogeneous focusing magnetic field in which the klinotron effect is applied to improve the efficiency of energy exchange between the tubular electron beam and electromagnetic field of the open coaxial cavity is investigated. It is shown that in this device with double electron optics at f0 = 100 GHz and at V0 = 2,8 kV, B0max 0, 4...0, 436 T, B0min = 0, 266...0,338 T, I0 = 3...10 A of relatively thick double electron beams (Δr r0 =0,01) the efficiency 10...18 % is achieved.
Keywords
electromagnetic fields; electron beams; electron optics; magnetic fields; microwave tubes; coaxial klinoorotron; double electron optics; electromagnetic field; energy exchange; frequency 100 GHz; inhomogeneous focusing magnetic field; klinotron effect; open coaxial cavity; tubular electron beam; voltage 2 kV; voltage 8 kV; Coaxial components; Electromagnetic fields; Electromagnetic waveguides; Electron beams; Electron optics; Erbium; Informatics; Magnetic fields; Optical design; Optical resonators; coaxial klinoorotron; inhomogeneous magnetic field; thick double electron beams;