DocumentCode :
2926132
Title :
21.6: Progress in ICEPIC simulation of commercial strapped magnetrons as HPM sources
Author :
Keisling, John D. ; Lazo, Maximo S.
Author_Institution :
AFRL, RDHE (SAIC), Albuquerque, NM, USA
fYear :
2010
fDate :
18-20 May 2010
Firstpage :
515
Lastpage :
516
Abstract :
We investigated the effects of heater filament current, input voltage, axial tube dimensions, grid resolution, and emission parameters on ICEPIC simulations of an experimental strapped 922 MHz magnetron with axial power extraction and a thermionic, helical cathode (Twisleton, J.R.G., "Twenty-kilowatt 890 MHz Continuous-Wave Magnetron." Proc. IEEE, vol. Ill, No. 1, January 1964). This type of device had not previously been successfully simulated using ICEPIC.
Keywords :
magnetrons; thermionic cathodes; HPM sources; ICEPIC simulation; axial power extraction; axial tube dimension; commercial strapped magnetron; emission parameter; frequency 922 MHz; grid resolution; heater filament current; input voltage; thermionic helical cathode; Cathodes; Curve fitting; Electron tubes; Geometry; Magnetic fields; Magnetrons; Resonant frequency; Steady-state; Thermionic emission; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Vacuum Electronics Conference (IVEC), 2010 IEEE International
Conference_Location :
Monterey, CA
Print_ISBN :
978-1-4244-7098-3
Type :
conf
DOI :
10.1109/IVELEC.2010.5503484
Filename :
5503484
Link To Document :
بازگشت