Title
Design of the insulating supports in medium voltage dry-type transformers
Author
Gonzalez V, E. ; Gómez, P. ; Espino-Cortés, F.P.
Author_Institution
SEPI - ESIME, Zacatenco Nat. Polytech. Inst., Mexico City, Mexico
fYear
2011
fDate
5-8 June 2011
Firstpage
45
Lastpage
48
Abstract
In this work, a study of the parameters that affect the breakdown voltage in dry-type transformer is performed. The effect of the high operation temperatures of the transformer on the voltage breakdown in the insulating supports is investigated and the electric field distribution on different profiles of these supports is modeled using Finite Element Method (FEM). A design of the insulating support that can help to reduce its length without increasing the possibility of breakdown is discussed.
Keywords
electric fields; finite element analysis; power transformer insulation; FEM; electric field distribution; finite element method; high operation temperatures; insulating supports; medium voltage dry-type transformers; voltage breakdown; Electric breakdown; Electric fields; Finite element methods; Ocean temperature; Oil insulation; Power transformer insulation; Windings; FEM; breakdown; dry-type transformer; electric field; supports;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation Conference (EIC), 2011
Conference_Location
Annapolis, MD
ISSN
pending
Print_ISBN
978-1-4577-0278-5
Electronic_ISBN
pending
Type
conf
DOI
10.1109/EIC.2011.5996113