Abstract
Compact stator end windings of large turbine generators are stressed by tangentially stressed boundary surfaces. To achieve an optimal design, the electrical field strength has to be below the partial discharge (PD) inception field strength. In regular operation - especially for air cooled machines - several environmental impacts could affect the PD inception field strength inside stator end winding configurations, especially the influence of dust, dirt and ambient moisture. Therefore investigations are necessary to classify contamination influences in regard to its potential to cause surface corona.
Keywords
corona; electric fields; machine windings; partial discharges; turbogenerators; air cooled machine; compact stator end winding configuration; contamination; electrical field strength; surface PD inception field strength; surface corona; surface partial discharge inception field strength; tangential electrically stressed boundary surface; turbine generator; Moisture; Partial discharges; Pollution; Pollution measurement; Surface contamination; Surface discharges; Voltage measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation Conference (EIC), 2011
Conference_Location
Annapolis, MD
ISSN
pending
Print_ISBN
978-1-4577-0278-5
Electronic_ISBN
pending
Type
conf
DOI
10.1109/EIC.2011.5996128
Filename
5996128
Link To Document