DocumentCode :
2927778
Title :
Tracking stator bar condition by on-line partial discharge measurements
Author :
McDermid, W. ; Black, T.
Author_Institution :
Manitoba Hydro, Winnipeg, MB, Canada
fYear :
2011
fDate :
5-8 June 2011
Firstpage :
323
Lastpage :
326
Abstract :
A total of 24 new stator bar windings in hydrogenerators were equipped with 80 pF permanent couplers for on-line partial discharge measurements beginning in 1979. This paper summarizes some of the changes in the PD characteristics that have occurred over the years and correlates significant changes with the condition of the windings.
Keywords :
hydroelectric generators; partial discharge measurement; stators; PD characteristics; capacitance 80 pF; hydrogenerators; online partial discharge measurements; permanent couplers; stator bar windings; tracking stator bar condition; Couplers; Partial discharge measurement; Stator bars; Stator windings; Stress control; Windings; partial discharge; rotating machines;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation Conference (EIC), 2011
Conference_Location :
Annapolis, MD
ISSN :
pending
Print_ISBN :
978-1-4577-0278-5
Electronic_ISBN :
pending
Type :
conf
DOI :
10.1109/EIC.2011.5996171
Filename :
5996171
Link To Document :
بازگشت