DocumentCode
2929559
Title
LORINE: Neutron Emission LOcatoR by SOI detectors
Author
Hamrita, H. ; Kondrasovs, V. ; Borbotte, J.M. ; Saurel, N. ; Normand, S.
Author_Institution
Lab. Capteurs et Archit. Electron., CEA, Gif-sur-Yvette, France
fYear
2009
fDate
7-10 June 2009
Firstpage
1
Lastpage
3
Abstract
The aim of this work is to develop a fast Neutron Emission LOcatoR based on silicon on Insulator detector (LORINE). This locator could be used in presence of significant flux of gamma radiation. With the collaboration of the CEA Valduc LORINE was developed to locate areas containing a significant amount of actinide during the dismantling operations of equipment. Location of fast neutron sources does not yet exist so compactly and it could be operated in the presence of very important gamma radiation flux.
Keywords
neutron detection; silicon radiation detectors; LORINE; SOI detector; fast neutron emission; fast neutron source; gamma radiation flux; silicon-on-insulator detector; Capacitance; Detectors; Gamma rays; Insulation; Mechanical factors; Neutrons; Protons; Radioactive decay; Silicon on insulator technology; Strips; Neutron detector; SOI; Silicon detector;
fLanguage
English
Publisher
ieee
Conference_Titel
Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA), 2009 First International Conference on
Conference_Location
Marseille
Print_ISBN
978-1-4244-5207-1
Electronic_ISBN
978-1-4244-5208-8
Type
conf
DOI
10.1109/ANIMMA.2009.5503663
Filename
5503663
Link To Document