Title :
Dielectric strength testing: Transient over-voltage withstand testing
Author_Institution :
Richard Nute Product Safety Consultant, Bend, OR, USA
Abstract :
Contrary to what is published elsewhere, electric strength testing is not a margin above the voltage to which the insulation is subjected. Instead, the “hi-pot” test is to determine that the safeguard insulations will withstand the normally-occurring transient over-voltages. This paper discusses why electric strength greater than normal voltage is necessary, and the process of electric strength testing.
Keywords :
electric strength; insulation testing; overvoltage; dielectric strength testing; hi-pot test; normally-occurring transient over-voltages; transient over-voltage withstand testing; Electric breakdown; Insulation; Production; Solids; Test equipment; Transient analysis; “hi-pot”; clearance; dielectric strength; electric strength; insulation; transient over-voltage;
Conference_Titel :
Product Compliance Engineering (ISPCE), 2015 IEEE Symposium on
Conference_Location :
Chicago, IL
DOI :
10.1109/ISPCE.2015.7138701