DocumentCode
2929751
Title
Dielectric strength testing: Transient over-voltage withstand testing
Author
Nute, Richard
Author_Institution
Richard Nute Product Safety Consultant, Bend, OR, USA
fYear
2015
fDate
18-20 May 2015
Firstpage
1
Lastpage
6
Abstract
Contrary to what is published elsewhere, electric strength testing is not a margin above the voltage to which the insulation is subjected. Instead, the “hi-pot” test is to determine that the safeguard insulations will withstand the normally-occurring transient over-voltages. This paper discusses why electric strength greater than normal voltage is necessary, and the process of electric strength testing.
Keywords
electric strength; insulation testing; overvoltage; dielectric strength testing; hi-pot test; normally-occurring transient over-voltages; transient over-voltage withstand testing; Electric breakdown; Insulation; Production; Solids; Test equipment; Transient analysis; “hi-pot”; clearance; dielectric strength; electric strength; insulation; transient over-voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Product Compliance Engineering (ISPCE), 2015 IEEE Symposium on
Conference_Location
Chicago, IL
Type
conf
DOI
10.1109/ISPCE.2015.7138701
Filename
7138701