• DocumentCode
    2930101
  • Title

    Over-voltage analyzing for High Speed Railway phase-separation switch

  • Author

    Gao, Guoqiang ; Yuan, Biaofeng ; Feng, Yansuang ; Wu, Guangning ; Zhou, Lijun ; Wang, Wangang ; Wang, Bo

  • Author_Institution
    Southwest Jiaotong Univ., Chengdu, China
  • fYear
    2011
  • fDate
    23-27 Oct. 2011
  • Firstpage
    207
  • Lastpage
    209
  • Abstract
    With the development of High Speed Railway (HSR) in China, the demand for increasing HSR´s speed become more and more intensively. Switch-ground automatic phase-separation convert is an efficient method to increasing HSR´s speed. But for the use of ground converting switch, over-voltage frequently appears at the process of phase-separation. It is harmful to equipments safety. In order to handle it, impacting factors on over-voltage have been studied insight. Relationship between the phase and over-voltage are analyzed. According to the analyzing result, the suitable switching on time for ground converting switch have been proposed.
  • Keywords
    high-voltage engineering; overvoltage; railway electrification; switchgear; ground converting switch; high speed railway phase-separation switch; over-voltage analyzing; switch-ground automatic phase-separation convert; Capacitance; Contacts; Power supplies; Resistance; Switches; Switching circuits; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electric Power Equipment - Switching Technology (ICEPE-ST), 2011 1st International Conference on
  • Conference_Location
    Xi´an
  • Print_ISBN
    978-1-4577-1273-9
  • Type

    conf

  • DOI
    10.1109/ICEPE-ST.2011.6122970
  • Filename
    6122970