DocumentCode :
2930232
Title :
A new method to detect the short circuit current in DC supply system based on the flexible Rogowski coil
Author :
Wang, Yan ; Zhai, Xiaoshe ; Song, Zhengxiang ; Geng, Yingsan
Author_Institution :
State Key Lab. of Electr. Insulation & Power Equip., Xi´´an Jiaotong Univ., Xi´´an, China
fYear :
2011
fDate :
23-27 Oct. 2011
Firstpage :
237
Lastpage :
240
Abstract :
The short circuit current in DC (Direct Current) supply system will rise to a risk value within a few milliseconds. The current limiter must detect this fault on microsecond level to restrict the amplitude of short circuit current more effectively. For the existing method, the shunt is always employed for such fault detection, where the time to detect the fault current is relative long and hard for the rapid detection. In this paper, a novel method based on the flexible Rogowski coil is proposed, where the differential signal and the integral signal of the Rogowski coil are combined to perform the relay protection function. The design method of the coil, the relative experiments and the simulation result of the relay protection system are all discussed in sequence. Firstly, the equivalent circuit of the Rogowski coil is established, in which the distributed parameters of the coil are calculated with the Finite Element Method. Secondly, the frequency response of the coil is calculated and validated experimentally. The parameters of the Rogowski coil can be adjusted and designed according to the simulation result. Finally, the simulation of the relay protection system is performed, which shows that the demand of short current protection in ship DC distribution system can be satisfied and the method proposed in this paper is verified.
Keywords :
equivalent circuits; fault current limiters; finite element analysis; frequency response; power distribution faults; relay protection; short-circuit currents; DC supply system; current limiter; differential signal; equivalent circuit; fault detection; finite element method; flexible Rogowski coil; frequency response; integral signal; relay protection function; ship DC distribution system; short circuit current detection; short current protection; Capacitance; Coils; Current measurement; Frequency measurement; Integrated circuit modeling; Short circuit currents; Voltage measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electric Power Equipment - Switching Technology (ICEPE-ST), 2011 1st International Conference on
Conference_Location :
Xi´an
Print_ISBN :
978-1-4577-1273-9
Type :
conf
DOI :
10.1109/ICEPE-ST.2011.6122978
Filename :
6122978