DocumentCode :
2930486
Title :
A novel techniques for step down converter implemented by high voltage operational amplifier
Author :
Tripetch, Kittipong
Author_Institution :
Div. of Electron. & Telecommun. Eng., Rajamangala Univ. of Technol. Suvarnabhumi, Muang, Thailand
fYear :
2012
fDate :
20-22 June 2012
Firstpage :
287
Lastpage :
292
Abstract :
This paper introduces techniques which can be used to step down input voltage. It is different from traditional idea which use duty cycle concept. By using frequency domain concept low pass active filter can be used to step down input voltage. While high pass active filter can be used to step up output voltage. High precision supply voltage at 1mV step can be generated by the proposed techniques without the series resistor and switches more than 1000 pieces if the cut off frequency of the filter is accurate enough. If the input voltage is not as high as 15 volt, op-amp model LF353 can be used to implement step down converter.
Keywords :
active filters; frequency-domain analysis; high-pass filters; low-pass filters; operational amplifiers; power convertors; LF353 op-amp model; duty cycle concept; frequency-domain concept; high-pass active filter; high-voltage operational amplifier; low-pass active filter; series resistor; step-down converter; voltage 1 mV; Active filters; Operational amplifiers; Phase locked loops; Pulse width modulation; Voltage control; Voltage measurement; Buck-Boost converter; Cuk converter; ac to dc converter; step up and down converter;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM), 2012 International Symposium on
Conference_Location :
Sorrento
Print_ISBN :
978-1-4673-1299-8
Type :
conf
DOI :
10.1109/SPEEDAM.2012.6264519
Filename :
6264519
Link To Document :
بازگشت