Title :
Position resolution estimation for centroid formula in strip detectors
Author :
Samedov, Victor V.
Author_Institution :
Moscow Eng. Phys. Inst., State Univ., Moscow, Russia
Abstract :
In a strip detector the absorption of energy occurs in a long strip, whereas the readout provides by two detectors positioned at the ends of the strip. Accuracy of coordinate estimation or position resolution is the crucial characteristic for using strip detectors for tracking and imaging. It is obvious, that the position resolution is closely connected with the energy resolution of detectors. In this paper the relation between the position and the energy resolutions was derived. This relation accounts for the correlation between the signal fluctuations of readout detectors, as this is essential for the position resolution of strip detectors. Using this formula and the data of experimental calibration one can determine the position resolution of the strip detector for given coordinate of an incident particle.
Keywords :
position sensitive particle detectors; radiation detection; centroid formula; coordinate estimation accuracy; detector energy resolution; detector position resolution; energy absorption; position resolution accuracy; position resolution estimation; readout detector signal fluctuations; strip detectors; Absorption; Calibration; Energy resolution; Fluctuations; Image resolution; Position sensitive particle detectors; Signal resolution; Strips; X-ray detection; X-ray detectors; Correlation between the signals; Energy resolution; Position resolution; Position sensitive detectors; Strip detectors;
Conference_Titel :
Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA), 2009 First International Conference on
Conference_Location :
Marseille
Print_ISBN :
978-1-4244-5207-1
Electronic_ISBN :
978-1-4244-5208-8
DOI :
10.1109/ANIMMA.2009.5503758