• DocumentCode
    2931660
  • Title

    Phase calibration of the Very Long Baseline Array (VLBA)

  • Author

    Rogers, A.E.E. ; Corey, B.E. ; Nesman, E.F.

  • Author_Institution
    MIT Haystack Obs., Westford, MA, USA
  • fYear
    1992
  • fDate
    1-5 June 1992
  • Abstract
    Summary form only given. The delay through a microwave receiver can be calibrated by injecting short-duration pulses (<25-ps risetime) with constant repetition rate (typically 1 MHz) through a coupler into the input of the receiver. The phases of the tones generated by the pulse train are measured to determine the receiver phase and group delay. For a calibration tone of -100 dBm injected through a 40-dB coupler the pulse cal temperature is 0.7 K averaged over 1 MHz. This tone can be measured to within 0.3 degrees in 1 s when extracted from a 1 MHz bandwidth for a receiver with a 30-K system temperature. The group delay is determined from the phases of several tones over the observing band.<>
  • Keywords
    calibration; microwave antenna arrays; radioastronomical techniques; radiotelescopes; radiowave interferometry; 1 MHz; 30 K; calibration tone; constant repetition rate; delay; group delay; microwave receiver; pulse cal temperature; pulse train; receiver phase; short-duration pulses; Calibration; Delay; Extraterrestrial measurements; Microwave generation; Phase measurement; Phased arrays; Pulse generation; Pulse measurements; Receivers; Temperature;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Symposium Digest, 1992., IEEE MTT-S International
  • Conference_Location
    Albuquerque, NM, USA
  • ISSN
    0149-645X
  • Print_ISBN
    0-7803-0611-2
  • Type

    conf

  • DOI
    10.1109/MWSYM.1992.188261
  • Filename