• DocumentCode
    2933651
  • Title

    Development of miniaturized mass-flow meter for an axial flow blood pump using a curved cannula

  • Author

    Kosaka, Ryo ; Nishida, Masahiro ; Maruyama, Osamu ; Yamane, Takashi

  • Author_Institution
    Nat. Inst. of Adv. Ind. Sci. & Technol. (AIST), Tsukuba, Japan
  • fYear
    2010
  • fDate
    Aug. 31 2010-Sept. 4 2010
  • Firstpage
    2513
  • Lastpage
    2516
  • Abstract
    To grasp conditions of patients and implantable artificial hearts, it is important to measure the pump flow rate continuously and noninvasively. In this study, a miniaturized mass-flow meter for discharged patients with an implantable axial flow blood pump was developed. The mass-flow meter makes use of centrifugal force generated by mass-flow rate around the curved cannula. Based on the computational fluid dynamics (CFD) analysis, the prototype miniaturized mass-flow meter was developed. Two strain gauges were adopted as the sensor elements. The first strain gauge, attached to the straight area, measured static pressure. The second strain gauge, attached to the curved area, measured static pressure and the centrifugal force. By subtracting the output of the first strain gauge from the output of the second strain gauge, the mass-flow rate was determined. In the evaluation tests using the mock-up circulation loop, the mass-flow meter was compared to a commercial flow meter. As a result, measurement error was less than 1.0 L/min, and time delay was less than 0.2 s. We confirmed that the miniaturized mass-flow meter could accurately measure the mass-flow rate continuously and noninvasively.
  • Keywords
    blood flow measurement; cardiovascular system; computational fluid dynamics; flowmeters; prosthetics; strain gauges; strain sensors; CFD analysis; axial flow blood pump; centrifugal force; computational fluid dynamics; curved cannula; implantable artificial hearts; measurement error; miniaturized mass flow meter; mock-up circulation loop; sensor; static pressure; strain gauges; time delay; Blood; Computational fluid dynamics; Fluid flow measurement; Force; Heart; Pressure measurement; Strain; Biomechanics; Biomedical Engineering; Computer Simulation; Equipment Design; Heart Failure; Heart, Artificial; Heart-Assist Devices; Hemorheology; Humans; Hydrodynamics; Implants, Experimental; Miniaturization; Monitoring, Physiologic; Pressure; Reproducibility of Results;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2010 Annual International Conference of the IEEE
  • Conference_Location
    Buenos Aires
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-4123-5
  • Type

    conf

  • DOI
    10.1109/IEMBS.2010.5626875
  • Filename
    5626875