• DocumentCode
    2934015
  • Title

    AC-DC difference precision measurement of μpot

  • Author

    Wei, Yih-cheng ; Tsai, Hsiu-Ju

  • Author_Institution
    Electr. Meas. Lab., Ind. Technol. Res. Inst., Hsinchu, Taiwan
  • Volume
    3
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    1834
  • Abstract
    Many electrical standard laboratories use μpots as the primary standards for low ac voltage measurement. To determine the ac-dc difference of a μpot usually requires a transfer standard which has high input impedance for the standard values transferred from a standard μpot through a step-down procedure. In order to lower the uncertainty of the μpot ac-dc difference measurement, after several step-down procedures at low voltage range, a precision comparison method is introduced
  • Keywords
    measurement standards; transfer standards; voltage measurement; μpots; AC-DC difference; comparison method; electrical standard laboratories; precision measurement; primary standards; step-down procedures; transfer standard; voltage measurement; Frequency; Impedance measurement; Laboratories; Low voltage; Measurement standards; Resistors; Testing; Uncertainty; Voltage control; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference, 1999. IMTC/99. Proceedings of the 16th IEEE
  • Conference_Location
    Venice
  • ISSN
    1091-5281
  • Print_ISBN
    0-7803-5276-9
  • Type

    conf

  • DOI
    10.1109/IMTC.1999.776137
  • Filename