  • Abstract
    Magneto-impedance (MI) response in single glass-coated amorphous microwire and, respectively glass-coated amorphous microwires array in the presence of Fe-based magnetic liquid was studied. Major differences of the magneto-impedance response are obtained when microwires array is used. Magneto-impedance was strongly influenced by magnetic liquid covering only about 8% of array.
  • Keywords
    amorphous magnetic materials; biomagnetism; biosensors; giant magnetoresistance; magnetic fluids; biomolecules detection; biosensor prototype; glass-coated amorphous microwires array; high sensitive magnetic GMI-based sensing elements array; magnetic liquid; magneto-impedance response; Amorphous magnetic materials; Amorphous materials; Biosensors; Coatings; Iron; Magnetic particles; Magnetic sensors; Molecular biophysics; Nanoparticles; Soft magnetic materials;