DocumentCode
2935249
Title
A Study of Distributing Parameters in High Voltage Transformer for HID ballast
Author
Dong, P. ; Cheng, K.E. ; Ho, S.
Author_Institution
Hong Kong Polytech. Univ., Kowloon
fYear
2006
fDate
8-12 May 2006
Firstpage
128
Lastpage
128
Abstract
This paper studies the effect of distributing parameters in high-voltage transformer. After calculated this parameters by finite element method, the values were validated by experiment result. Good agreement is found. Due to the leakage inductance and stray capacitance, the resonance exhibits certain electro magnetic interference to the circuit. So some methods must be used to reduce the values of distributing parameters in high-voltage transformer. In addition, the high voltage pulse with low current is easy to dissipate in the air.
Keywords
capacitance; electromagnetic interference; finite element analysis; high-voltage techniques; inductance; power transformers; distributing parameters; electromagnetic interference; finite element method; high intensity discharge ballast; high-voltage transformer; leakage inductance; resonance; stray capacitance; Capacitance; Electronic ballasts; Finite element methods; Inductance; Interference; Low voltage; Magnetic circuits; Magnetic resonance; RLC circuits; Voltage transformers;
fLanguage
English
Publisher
ieee
Conference_Titel
Magnetics Conference, 2006. INTERMAG 2006. IEEE International
Conference_Location
San Diego, CA
Print_ISBN
1-4244-1479-2
Type
conf
DOI
10.1109/INTMAG.2006.375628
Filename
4261562
Link To Document