DocumentCode :
2937042
Title :
Time domain simulation of EUT effect on a guided-wave EMP simulator´s field uniformity
Author :
Li-jun Yao ; Ning Kang ; Tao Shen
Author_Institution :
Electromagn. Environ. Effect Lab., Beijing Inst. of Radio Metrol. & Meas., Beijing, China
fYear :
2012
fDate :
6-9 Nov. 2012
Firstpage :
139
Lastpage :
142
Abstract :
Three different dimensions of equipments under test (EUT) are simulated under two placement conditions in a guided-wave electromagnetic pulse (EMP) simulator and the field uniformity within the test zone of the simulator are computed correspondingly. Therefore two electromagnetic compatibility (EMC) test guidelines are verified which are in consistent with the requirements in transverse electromagnetic (TEM) waveguide facilities and very important to ensure the validation of the test results.
Keywords :
electromagnetic compatibility; electromagnetic pulse; electronic equipment testing; test facilities; time-domain analysis; waveguides; EMC test guidelines; EUT effect; TEM waveguide facility; electromagnetic compatibility test guidelines; equipment under test; guided-wave EMP simulator field uniformity; guided-wave electromagnetic pulse simulator; simulator test zone; time-domain simulation; transverse electromagnetic waveguide facility; Analytical models; Electromagnetic compatibility; Electromagnetic waveguides; Electromagnetics; Guidelines; Metals; Numerical models; EMP; EUT effect; FIT; field uniformity; guided-wave simulator; simulation;
fLanguage :
English