    Comparative Analysis of CCHP Systems Based on Different Gas Turbine Cycles Applied in North of China

  • Author

    Wang, Wei ; Tan, Xu ; Jin, Liang ; Zhong, Zhao-Yi

  • Author_Institution
    Sch. of Energy & Power Eng., Dalian Univ. of Technol., Dalian, China
  • fYear
    2011
  • fDate
    25-28 March 2011
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    CCHP (Combined Cooling, Heating & Power) system is a highly efficient and flexible way to utilize natural gas, which attracts more and more attention. Two systems are presented for a vacation village in north of china, both of which generate electricity with gas turbine and utilize natural gas as fuel. One of systems adopts Brayton cycle, and the other adopts recuperative cycle. The analysis focuses on the influence of the outlet temperature of heat-recovery boiler, the efficiency of gas fired boiler and the ratio of thermal load and power load on the primary energy ratio and the exergy efficiency, when the systems are running in northern china of winter. The results can provide reference for the design and lectotype of CCHP system.
  • Keywords
    boilers; exergy; gas turbines; heat recovery; steam power stations; trigeneration; Brayton cycle; CCHP systems; combined cooling heating and power system; exergy efficiency; gas fired boiler; gas turbine cycles; heat-recovery boiler; natural gas utilization; power load; primary energy ratio; recuperative cycle; thermal load; Boilers; Economics; Fuels; Thermal loading; Turbines; Waste heat;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power and Energy Engineering Conference (APPEEC), 2011 Asia-Pacific
  • Conference_Location
    Wuhan
  • ISSN
    2157-4839
  • Print_ISBN
    978-1-4244-6253-7
  • Type

    conf

  • DOI
    10.1109/APPEEC.2011.5748942
  • Filename
    5748942