    Calorimetric thermal voltage converter as a wideband calculable standard of ac-dc difference

  • Author

    Filipski, P.S. ; Clark, R.F. ; Paulusse, D.C.

  • Author_Institution
    Inst. for Nat. Meas. Stand., Nat. Res. Council of Canada, Ottawa, Ont., Canada
  • fYear
    1998
  • fDate
    6-10 July 1998
  • Firstpage
    167
  • Lastpage
    168
  • Abstract
    A calorimetric thermal voltage converter is used at the National Research Council of Canada as a high-frequency reference standard of the ac-dc difference. This paper describes its redesigned realization. Calculations and test results in the 10 Hz-100 MHz frequency range are shown.
  • Keywords
    calorimeters; convertors; transfer standards; voltage measurement; 10 Hz to 100 MHz; AC-DC difference; SMA-type connector; calorimetric thermal voltage converter; high-frequency reference standard; modified design; wideband calculable standard; Analog-digital conversion; Coaxial components; Connectors; Copper; Councils; Frequency conversion; Resistors; Testing; Voltage; Wideband;