Abstract :
We have measured the efficiency, timing and pulse heights in several types of microstrip Gas Chambers with plastic substrates passivated with a thin Nickel layer. We used as active gas mixtures Argon/Isobutane and CF4/Isobutane. We placed the detectors in a secondary beam at TRIUMF tuned to a momentum of 100 MeV/c of pions, muons and electrons. Preliminary results indicate good efficiency for minimum ionizing particles in Argon/Isobutane mixtures but lesser efficiency in CF4 based gases indicating the importance of high quality preamplifiers to increase the signal to noise ratio
Keywords :
argon; electron detection; meson detection; muon detection; position sensitive particle detectors; proportional counters; Ar; CF4/isobutane mixture; Ni; active gas mixtures; argon/isobutane mixture; electrons; microstrip gas counters; minimum ionizing particles; muons; pions; plastic substrates; Argon; Counting circuits; Electron beams; Mesons; Microstrip; Nickel; Plastics; Pulse measurements; Testing; Timing;