• DocumentCode
    2944320
  • Title

    Dynamics calibration using inverse dynamics and LS technique — An application to the human body

  • Author

    Venture, Gentiane ; Gautier, Maxime

  • Author_Institution
    Dept. of Mech. Syst. Eng., Tokyo Univ. of Agric. & Technol., Koganei, Japan
  • fYear
    2012
  • fDate
    11-14 July 2012
  • Firstpage
    508
  • Lastpage
    513
  • Abstract
    The human body is modeled as a humanoid robot with 34 dof and 15 links. The inverse dynamic model of the robot is linear in relation to 10 standard physical inertial parameters for each link which are the mass, the 6 inertia matrix coefficients and the 3 center of mass coordinates. For robotics control or simulation applications, a minimum number of b base parameters, b <; 150, can be identified by linear LS techniques using motion capture and foot/ground contact force/torque data measurements. But some base parameters are not well identified due to measuring errors and poor excitation. They have no statistical significant values and they can lose their physical meaning. Because these parameters have little contribution in the measured force/torque they can be eliminated from the model to calculate a subset of significant base parameters called the essential parameters [1], [2], [3]. For medical applications the physical anatomical meaningful values are needed for the 150 standard parameters of the 15 segments of the human body model, not only a minimal set of parameters. Based on the essential parameters we propose to calculate the LS solution with SVD factorization, which is the closest in 2 norm of a set of a priori anatomic values given by literature database. This solution keeps both the same minimum norm error given by the essential parameters and the physical anatomical meaning of the a priori values when the measuring noise and errors are small. Experimental results are presented and discussed.
  • Keywords
    calibration; force measurement; humanoid robots; least squares approximations; matrix algebra; medical robotics; noise measurement; singular value decomposition; torque measurement; SVD factorization; dynamic calibration; error measurement; essential parameters; foot-ground contact force-torque data measurements; human body model; humanoid robot; inertia matrix coefficients; inverse dynamics; linear LS techniques; literature database; mass coordinates; medical applications; motion capture; noise measurement; physical anatomical meaningful values; priori anatomic values; robotics control; standard physical inertial parameters; statistical significant values; Biological system modeling; Computational modeling; Joints; Robots; Standards; Vectors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Advanced Intelligent Mechatronics (AIM), 2012 IEEE/ASME International Conference on
  • Conference_Location
    Kachsiung
  • ISSN
    2159-6247
  • Print_ISBN
    978-1-4673-2575-2
  • Type

    conf

  • DOI
    10.1109/AIM.2012.6265993
  • Filename
    6265993