DocumentCode
2944445
Title
Inter-laboratory comparison of high direct voltage resistance dividers
Author
Yi Li ; Rungis, J. ; Kyu-Tae Kim ; Yong Myung Cho ; McComb, T.R. ; Dunn, J.G. ; van der Zwan, L. ; Hoffman, D.
Author_Institution
High Voltage Lab., CSIRO, Lindfield, NSW, Australia
fYear
1998
fDate
6-10 July 1998
Firstpage
210
Lastpage
211
Abstract
A 150 kV NML divider was used as a travelling standard in comparison tests against standard dividers maintained at KRISS of Korea and NRC of Canada. Useful results in terms of the relative ratio changes among the dividers under high voltages were obtained. The comparison tests were shown to be especially valuable for evaluating the ratio drifts of the dividers due to prolonged application of high voltage.
Keywords
dividing circuits; high-voltage techniques; 150 kV; KRISS; NML; NRC; high voltage resistance divider; inter-laboratory comparison test; ratio drift; travelling standard; Arm; Circuit noise; Electrical resistance measurement; Laboratories; Measurement standards; Power measurement; Resistors; Signal to noise ratio; Testing; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements Digest, 1998 Conference on
Conference_Location
Washington, DC, USA
Print_ISBN
0-7803-5018-9
Type
conf
DOI
10.1109/CPEM.1998.699871
Filename
699871