Abstract
The design of a three-dimensional laser Doppler anemometer for the T2 wind tunnel which can measure simultaneously and without disturbance the three instantaneous components of the velocity in a complex transonic flow is described. The design is an innovative one, including fiber optics and real-time signal processing, using a digitized Fourier transform. These technologies have been tested and qualified. The complete system allows systematic optical measurements for most experiments performed in the T2
Keywords
Doppler effect; anemometers; computerised picture processing; fast Fourier transforms; laser velocimeters; transonic flow; wind tunnels; T2 transonic wind tunnel; computerised picture processing; digitized Fourier transform; fiber optics; laser velocimeter; optical measurements; real-time signal processing; three dimensional Doppler anemometer; Fiber lasers; Fluid flow measurement; Fourier transforms; Optical design; Optical fibers; Optical signal processing; Performance evaluation; Signal design; Testing; Velocity measurement;