• DocumentCode
    29455
  • Title

    Very Low 1/f Noise and Radiation-Hardened CMOS Preamplifier for High-Sensitivity Search Coil Magnetometers

  • Author

    Rhouni, A. ; Sou, G. ; Leroy, P. ; Coillot, C.

  • Author_Institution
    Lab. of Electron. & Electromagn., Univ. Pierre et Marie Curie - Paris 6, Paris, France
  • Volume
    13
  • Issue
    1
  • fYear
    2013
  • fDate
    Jan. 2013
  • Firstpage
    159
  • Lastpage
    166
  • Abstract
    A 4 nV/√(Hz) at 10 Hz preamplifier with a 12-mW power consumption in complimentary metal-oxide-semiconductor 0.35 μm technology has been developed to go one step further in the integration of the preamplifier of a search coil magnetometer. The present application-specific integrated circuit (ASIC) preamplifier, combined with a 10-cm length, 12-mm diameter, and 15 000 turns search coil sensor demonstrates a noise equivalent magnetic induction as low as 2 pT/√(Hz) at 10 Hz and 14 fT/√(Hz) at 4 kHz. The measured current noise is only 46 fA/√(Hz). AC magnetometers (from 100 mHz to a few kHz) based on search coil sensors are used for space plasma physics investigations because of their excellent robustness and very high sensitivity. The present ASIC preamplifier offers a way to considerably save weight, volume, and power. This paper will focus on the design of the ASIC, driven by the following criteria: low thermal and 1/f noise, radiation hardness for space purpose, and power consumption.
  • Keywords
    1/f noise; CMOS analogue integrated circuits; application specific integrated circuits; coils; magnetometers; noise measurement; power consumption; preamplifiers; radiation hardening (electronics); sensitivity; sensors; 1/f noise; ASIC preamplifier; application-specific integrated circuit preamplifier; complimentary metal-oxide-semiconductor technology; current noise measurement; frequency 10 Hz; frequency 4 kHz; high-sensitivity search coil magnetometer; noise equivalent magnetic induction; power 12 mW; power consumption; preamplifier integration; radiation-hardened CMOS preamplifier; robustness; size 10 cm; size 12 mm; space plasma physics investigations; Application specific integrated circuits; Coils; Current measurement; Magnetic cores; Magnetometers; Noise; Noise measurement; Application specific integrated circuit (ASIC); low 1/f noise; magnetic sensors amplifier; noise equivalent magnetic induction (NEMI); radiation hardened; search coil magnetometer; space plasmas instruments;
  • fLanguage
    English
  • Journal_Title
    Sensors Journal, IEEE
  • Publisher
    ieee
  • ISSN
    1530-437X
  • Type

    jour

  • DOI
    10.1109/JSEN.2012.2211347
  • Filename
    6257413