DocumentCode :
2946187
Title :
Absolute frequency measurements and intercomparisons of He-Ne/CH/sup 4/ (/spl lambda/=3.39 /spl mu/m), CO/sub 2//OsO/sub 4/ (/spl lambda/=10.6 /spl mu/m) frequency stabilized lasers and Cs primary standard
Author :
Acef, O. ; Clairon, A. ; Hilico, L. ; Rovera, D.G. ; Kramer, G. ; Lipphardt, B. ; Shelkovnikov, A. ; Koval´chuk, E. ; Petrukhin, E. ; Tyurikov, D. ; Petrovskiy, M. ; Gubin, M.
Author_Institution :
BNM-LPTF, Obs. de Paris, Meudon, France
fYear :
1998
fDate :
6-10 July 1998
Firstpage :
258
Lastpage :
259
Abstract :
Results of absolute frequency calibration of the He-Ne/CH/sub 4/ transportable optical frequency standard (TOFS) and intercomparisons of the TOFS with CO/sub 2//OsO/sub 4/ OFS carried out on 1996-1997 by a collaboration of three organizations (Lebedev Institute, PTB, and BNM-LPTF) are reported.
Keywords :
atomic clocks; calibration; carbon compounds; frequency standards; gas lasers; helium; laser frequency stability; neon; osmium compounds; transfer standards; 10.6 micron; 3.39 micron; Allan variance; CO/sub 2/; CO/sub 2//OsO/sub 4/ optical frequency standard; Cs; Cs primary standard; He-Ne; He-Ne/CH/sub 4/ optical frequency standard; OsO/sub 4/; absolute frequency calibration; frequency stabilized lasers; standards intercomparisons; transportable standard; Calibration; Frequency measurement; Laser stability; Measurement standards; Measurement uncertainty; Reproducibility of results; Resonance; Standards development; Standards organizations; Transportation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements Digest, 1998 Conference on
Conference_Location :
Washington, DC, USA
Print_ISBN :
0-7803-5018-9
Type :
conf
DOI :
10.1109/CPEM.1998.699896
Filename :
699896
Link To Document :
بازگشت