Title :
Sea water flooded electric motor for 13,200 PSI
Author :
Flaherty, R.J. ; Walker, H.P.
Author_Institution :
Naval Ship Research and Development Laboratory, Annapolis, MD, USA
Abstract :
This paper describes the design, detaanidl s construction of a 7.5 HP, 30 Hertz, 8 pole, 600 RRM free flooded induction motor. Sea water is used for lubrication of bearings and as a cooling medium.
Keywords :
Bars; Bonding; Coatings; Coils; Conductive films; Copper; Insulation; Lamination; Protection; Stators;
Conference_Titel :
Engineering in the Ocean Environment - Digest of Technical Papers, 1970 IEEE International Conference on
DOI :
10.1109/OCEANS.1970.1160985