Title :
Testing of spark gap irreversibility under conditions of operation
Author :
Arsic, N. ; Kartalovic, N. ; Osmokrovic, P.
Author_Institution :
Fac. of Electr. Eng., Pristina Univ., Yugoslavia
Abstract :
The characteristics of a three-electrode spark gap are considered in this paper. Two types of three-electrode gas insulated spark gaps have been tested: a spark gap with a third electrode being inside the main electrode; and a spark gap with a separate third electrode. Both types of spark gaps were theoretically sized in the optimal way. Two characteristics are determined experimentally: (1) the influence of the triggering voltage rate-of-rise on the spark gap functioning; and (2) the degree of spark gap erosion vs. number of operations. Two types of gases were applied: SF/sub 6/ gas; and N/sub 2/ gas. Also, three electrode materials were used: copper; steel; and tungsten. The spark gap switching time and delay time are measured. Statistical analyses of results are also presented.
Keywords :
electrodes; gas insulated switchgear; power supplies to apparatus; pulse generators; pulsed power switches; spark gaps; switchgear testing; switching; N/sub 2/; SF/sub 6/; delay time; operations number; pulsed power switch testing; spark gap erosion; spark gap irreversibility; switching time; three-electrode spark gap characteristics; triggering voltage rate-of-rise; Building materials; Copper; Electrodes; Gas insulation; Gases; Spark gaps; Steel; Testing; Tungsten; Voltage;
Conference_Titel :
Pulsed Power Conference, 1995. Digest of Technical Papers., Tenth IEEE International
Conference_Location :
Albuquerque, NM, USA
Print_ISBN :
0-7803-2791-8
DOI :
10.1109/PPC.1995.599715