DocumentCode
2946402
Title
Self calibrating phase standard
Author
Lapuh, R. ; Visocnik, I. ; Svetik, Z.
Author_Institution
Inst. of Quality & Metrol., Ljubljana, Slovenia
fYear
1998
fDate
6-10 July 1998
Firstpage
274
Lastpage
275
Abstract
A phase standard, consisting of clock coupled phase generator and phase meter, is proposed. Phase generator is build around two direct digital synthesizers. Phase meter incorporates a single a/d converter and a floating point. A novel approach uses a/d converter in successive sampling of two signals and compensating for an introduced phase shift by taking into account a time interval between two sampling bursts.
Keywords
calibration; measurement standards; phase measurement; A/D converter; clock coupled phase generator; direct digital synthesizer; floating point; phase meter; phase shift compensation; phase standard; self calibration; signal sampling; Calibration; Circuits; Clocks; Detectors; Distortion measurement; Instruments; Phase detection; Phase measurement; Sampling methods; Switches;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements Digest, 1998 Conference on
Conference_Location
Washington, DC, USA
Print_ISBN
0-7803-5018-9
Type
conf
DOI
10.1109/CPEM.1998.699904