• DocumentCode
    2946964
  • Title

    Sampling power meter for low frequencies (45-55 Hz)

  • Author

    Jol, L.

  • Author_Institution
    NMi Van Swinden Lab., Delft, Netherlands
  • fYear
    1998
  • fDate
    6-10 July 1998
  • Firstpage
    279
  • Lastpage
    280
  • Abstract
    We have developed a new wattmeter based on digital sampling techniques. A unique feature of the system is the incorporation of the power source needed to feed the standard and device under test which greatly helps avoiding synchronisation problems. A bilateral comparison with SP in Sweden using a Pupin type travelling standard show good agreement between the results.
  • Keywords
    measurement standards; signal sampling; synchronisation; wattmeters; 45 to 55 Hz; Pupin travelling standard; digital sampling; low frequency device; power meter; power source; synchronisation; wattmeter; Circuit testing; Frequency synchronization; Phase measurement; Power generation; Reactive power; Sampling methods; Signal resolution; Voltage; Voltmeters; Wattmeters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 1998 Conference on
  • Conference_Location
    Washington, DC, USA
  • Print_ISBN
    0-7803-5018-9
  • Type

    conf

  • DOI
    10.1109/CPEM.1998.699907
  • Filename
    699907