DocumentCode :
2948324
Title :
Amplitude measurement technique for low duty cycle acoustic signals
Author :
Berstis, Knute A.
Author_Institution :
National Oceanographic Instrumentation Center
fYear :
1972
fDate :
13-15 Sept. 1972
Firstpage :
43
Lastpage :
46
Abstract :
A method of measuring the mean rms level of a low duty cycle acoustic signal using an inverting circuit and an integrating digital voltmeter (DVM) is described. The technique has the capability of taking many measurements which are recorded, in one configuration, through a data coupler on paper tape for analysis on a time share computer. The important system characteristics are noted and an estimate of the system error is tabulated.
Keywords :
Computer displays; Delay; Dynamic range; Inverters; Noise level; Sampling methods; Sea measurements; Signal resolution; Testing; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in the Ocean Environment, Ocean 72 - IEEE International Conference on
Conference_Location :
Newport, RI, USA
Type :
conf
DOI :
10.1109/OCEANS.1972.1161101
Filename :
1161101