DocumentCode
2950658
Title
Test Method Research of Magnetic Saturation Current of High-Frequency Transformer
Author
Ma, Hongtao ; Wang, Xiaojun ; Zhou, FenPing
Author_Institution
Coll. of Inf. Sci. & Eng., Hebei Univ. of Sci. & Technol., Shijiazhuang, China
Volume
2
fYear
2009
fDate
11-12 April 2009
Firstpage
712
Lastpage
714
Abstract
When the case of magnetic saturation of high-frequency transformer occurs in switching power supply, the effect to efficiency and output power as well as the harm to power switch tube are analyzed. A method of low-voltage, low-frequency square wave signal driving the primary coil of high-frequency transformer is introduced. By observing the current waveform of coil with oscilloscope and some following simple calculation, high-frequency magnetic transformer saturation current value can be obtained. The principle, related circuit, specific method, an example and result analysis of measuring are presented.
Keywords
coils; high-frequency transformers; switched mode power supplies; transformer testing; high-frequency transformer test method; magnetic saturation current; oscilloscope; power switch tube; primary coil; square wave signal; switching power supply; Circuit faults; Inductance; Inductors; Magnetic analysis; Magnetic cores; Magnetic switching; Permeability; Power supplies; Saturation magnetization; Testing; high-frequency transformer; magnetic staturation; test method;
fLanguage
English
Publisher
ieee
Conference_Titel
Measuring Technology and Mechatronics Automation, 2009. ICMTMA '09. International Conference on
Conference_Location
Zhangjiajie, Hunan
Print_ISBN
978-0-7695-3583-8
Type
conf
DOI
10.1109/ICMTMA.2009.145
Filename
5203532