• DocumentCode
    2951133
  • Title

    Processing Magnetic Resonance Images for CAD Model development of Prosthetic Limbs Socket

  • Author

    Udai, Arun Dayal ; Sinha, Amarendra Nath

  • Author_Institution
    Dept. of Mech. Eng., Birla Inst. of Technol., Ranchi
  • fYear
    2008
  • fDate
    8-10 Dec. 2008
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    Magnetic resonance imagery and computed tomography (MRI/CT) scan is realized as a powerful technology for mapping soft tissue sections for diagnosis of internal human body parts since decades. These `maps´ give different biomedical and anatomical information for early diagnosis of any disease. In the current work MRI scan data is utilized for building up of computer aided design (CAD) model for amputee´s artificial limb socket. The method utilizes the information stored in DICOM images obtained after MRI scan and processing its bitmap image counterpart, to generate section cloud data. These cloud data are piled up together to build volume cloud. The method uses reverse engineering (RE) technique to develop a CAD surface model which involves data filtering, segmentation, curves processing and surface development. The CAD model may be utilized for making precise positive mould for prosthetic limb socket manufacturing. It also finds its application in modern biomechanical simulation, virtual surgery, telemedical information systems and computer assisted documentation and education.
  • Keywords
    CAD; artificial limbs; biomedical MRI; computerised tomography; curve fitting; image segmentation; reverse engineering; surface fitting; CAD model development; CAD surface model; DICOM images; MRI scan data; artificial limb socket; biomechanical simulation; bitmap image counterpart; cloud data; computed tomography scan; computer aided design model; computer assisted documentation; curves processing; data filtering; data segmentation; disease; internal human body parts diagnosis; magnetic resonance imagery; magnetic resonance images; prosthetic limb socket manufacturing; prosthetic limbs socket; reverse engineering technique; soft tissue sections; surface development; telemedical information systems; virtual surgery; Biological system modeling; Biological tissues; Clouds; Computed tomography; Coronary arteriosclerosis; Humans; Magnetic resonance; Magnetic resonance imaging; Prosthetic limbs; Sockets; CAD model; MRI scan; Prosthetics;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial and Information Systems, 2008. ICIIS 2008. IEEE Region 10 and the Third international Conference on
  • Conference_Location
    Kharagpur
  • Print_ISBN
    978-1-4244-2806-9
  • Electronic_ISBN
    978-1-4244-2806-9
  • Type

    conf

  • DOI
    10.1109/ICIINFS.2008.4798343
  • Filename
    4798343