Title :
Optical magnetic field diagnostics for the MC1 flux compression generator experiments
Author :
Veeser, L.R. ; Rodriguez, P.J. ; Marshall, B.R. ; Lewis, W. ; Tatsenko, O.M.
Author_Institution :
Los Alamos Nat. Lab., NM, USA
Abstract :
We describe the optical diagnostics used to measure magnetic fields up to 11 MGauss (1100 T) produced by Russian MC1 magnetic flux compression generators propelled by American high explosives in a joint experiment. The fields were measured by Faraday rotation in glass samples placed between thin polarizers. Light was introduced and collected in multi-mode fiber optics, allowing the laser light source and the recording instrumentation to be housed in a bunker about 20 m from the explosion. Great care was taken to keep the volume of the diagnostics small so that they would survive the generator implosions long enough to complete the measurements.
Keywords :
Faraday effect; explosions; fibre optic sensors; magnetic field measurement; measurement by laser beam; power supplies to apparatus; pulse generators; pulsed power technology; 11 MG; Faraday rotation; MC1 flux compression generator; glass samples; high explosives; laser light source; magnetic fields measurement; multi-mode fiber optics; optical magnetic field diagnostics; recording instrumentation; thin polarizers; Explosives; Fiber lasers; Glass; Magnetic field measurement; Magnetic fields; Magnetic flux; Optical fiber polarization; Optical fibers; Propulsion; Rotation measurement;
Conference_Titel :
Pulsed Power Conference, 1995. Digest of Technical Papers., Tenth IEEE International
Conference_Location :
Albuquerque, NM, USA
Print_ISBN :
0-7803-2791-8
DOI :
10.1109/PPC.1995.599753