DocumentCode
2953103
Title
A three-coil RF probe-head at 2.35 T: Potential applications to the 23Na and to the hyperpolarized 129Xe MRI in small animals
Author
Asfour, Aktham
Author_Institution
INSERM, GIN, Grenoble, France
fYear
2010
fDate
Aug. 31 2010-Sept. 4 2010
Firstpage
5693
Lastpage
5699
Abstract
We present in this paper a dedicated home-built RF probe-head for the MRI of rat brain at 2.35 T. This probe consists of an association of three coils: a double-tuned birdcage coil, which could be used for both transmitting and receiving, and a single-tuned surface coil that is used for the only receiving. This single-tuned coil is actively decoupled from the double-tuned volume coil. The active decoupling is based on the pole insertion technique using PIN diodes circuitry. This development was initially motivated by its potential and future application to the brain perfusion measurements by the MRI of hyperpolarized xenon-129 (HP 129Xe). However, one of underlying ideas behind this work is to proceed well beyond this specific application. Particularly, the developed coil could also be dedicated for the sodium-23 (23Na) MRI in the rat brain. Indeed we tried to make the design versatile, simple and easy to replicate by other research groups, with a low cost, minimum development time and accepted performances. We believe that this design could by useful for groups who consider building own hardware. This is why we describe in some details the practical aspects of the workbench design as well as the coil characterization. For simplicity reasons, the first results of developed prototype were obtained at 100 MHz and 26.4 MHz (proton and sodium-23 frequencies at 2.35 T). MR images of phantoms were realized. In-vivo 1H images and 23Na spectra of the rat brain were also obtained. Future validation would concern the MRI of HP 129Xe.
Keywords
biomedical MRI; brain; p-i-n diodes; probes; sodium; MRI; Na; PIN diodes; brain perfusion; double-tuned birdcage coil; magnetic flux density 2.35 T; phantoms; pole insertion technique; rat brain; three-coil RF probe-head; Capacitors; Coils; Inductors; Magnetic resonance imaging; Protons; Radio frequency; Resonant frequency; Hyperpolarized xenon-129; MRI; Proton; RF double-tuned coils; Rat; active decoupling; sodium-23; Animals; Brain; Electricity; Electronics, Medical; Magnetic Resonance Imaging; Phantoms, Imaging; Protons; Radio Waves; Rats; Reproducibility of Results; Sodium; Xenon;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society (EMBC), 2010 Annual International Conference of the IEEE
Conference_Location
Buenos Aires
ISSN
1557-170X
Print_ISBN
978-1-4244-4123-5
Type
conf
DOI
10.1109/IEMBS.2010.5627882
Filename
5627882
Link To Document