• DocumentCode
    2953806
  • Title

    Feedback cancellation in hearing aids

  • Author

    Kates, James

  • Author_Institution
    City Univ. of New York, NY, USA
  • fYear
    1990
  • fDate
    3-6 Apr 1990
  • Firstpage
    1125
  • Abstract
    Feedback cancellation in hearing aids is discussed. It involves estimating the feedback signal and subtracting it from the microphone input signal. The system described updates the estimated feedback path whenever changes are detected in the feedback behavior. The normal hearing-aid processing is then interrupted, a probe signal is injected into the system, and a set of filter coefficients is adjusted to give an estimate and the feedback path. Both LMS adaptive filter and Wiener filter approaches were simulated, with the Wiener filter giving better performance at poor signal-to-noise ratios. The simulation results indicate that feedback suppression in excess of 10 dB is possible
  • Keywords
    adaptive filters; digital simulation; feedback; hearing aids; signal detection; signal processing; LMS adaptive filter; Wiener filter; feedback signal; feedback suppression; hearing aids; simulation; Adaptive filters; Auditory system; Feedback; Hearing aids; Least squares approximation; Microphones; Noise cancellation; Probes; Signal processing; Signal to noise ratio; Vents; Wiener filter;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Acoustics, Speech, and Signal Processing, 1990. ICASSP-90., 1990 International Conference on
  • Conference_Location
    Albuquerque, NM
  • ISSN
    1520-6149
  • Type

    conf

  • DOI
    10.1109/ICASSP.1990.116141
  • Filename
    116141