DocumentCode
2956153
Title
Design of Battery System of Emergency Power Supply for Auxiliary Fan in the Coal-Mine
Author
Huang Kai ; Li Zhigang ; Yang Chunwen
Author_Institution
Province-Minist. Joint Key Lab. of Electromagn. Field & Electr. Apparatus Reliability, Hebei Univ. of Technol., Tianjin, China
fYear
2011
fDate
30-31 July 2011
Firstpage
1
Lastpage
6
Abstract
To improve the safety and reliability of local ventilation of heading face in the coal-mine and prevent gas accumulation effectively, the paper develops a flameproof 660V- high power three-phase emergency power supply (EPS) for auxiliary fan in the mine. The paper illustrates the design and implementation of the battery system which is the core of the EPS, including the design of constitution of high-voltage battery, high power charging power supply, charging circuit based on PLC, and circuit for charging protection and equilibrium of batteries.
Keywords
coal; emergency power supply; fans; mining; reliability; safety; secondary cells; ventilation; PLC; auxiliary fan; battery equilibrium; battery system design; charging circuit; charging protection; coal-mine; emergency power supply; flameproof high-power three-phase EPS; gas accumulation; high-power charging power supply; high-voltage battery; ventilation reliability; ventilation safety; Batteries; Control systems; Discharges; Iron; Lithium; Switching circuits; Voltage control;
fLanguage
English
Publisher
ieee
Conference_Titel
Control, Automation and Systems Engineering (CASE), 2011 International Conference on
Conference_Location
Singapore
Print_ISBN
978-1-4577-0859-6
Type
conf
DOI
10.1109/ICCASE.2011.5997772
Filename
5997772
Link To Document