Abstract :
In this paper, indirect control theory is proposed for a 4-leg shunt active power filter (SAPF) to compensate reactive power and balance the load currents. The control for the fourth leg is made different from the other authors by using 0 as the neutral current reference. All simulations performed by using Matlab-Simulink show the effectiveness of the proposed solution.
Keywords :
active filters; power filters; power supply quality; 4-leg shunt active power filter; Matlab-Simulink; indirect control theory; neutral current reference; power quality problems; reactive power; unbalance compensation; Active filters; Current measurement; Power filters; Power quality; Reactive power; Voltage control; Voltage measurement; active power filter; indirect control; unbalance;