    A 350 kV dual resonant transformer for charging a 40 pF PFL at kilo-Hertz rep-rates

  • Author

    Scott, M.C. ; O´Loughlin, James P. ; Copeland, R.P.

  • Author_Institution
    Maxwell Labs. Inc., Albuquerque, NM, USA
  • Volume
    2
  • fYear
    1995
  • fDate
    3-6 July 1995
  • Firstpage
    1466
  • Abstract
    A dual resonant transformer, capable of charging a 40 pF pulse forming line to 350 kV, has been developed. Peak repetition rates of two kHz have been obtained with the use of a self-break high pressure hydrogen spark gap switch. The primary energy store of the device consists of 17.6 nF at 30 kV. This paper discusses the design of the transformer, the development of the high pressure hydrogen switch, and the use of a high pressure SF/sub 6/ environment to house the pulse transformer. Also the method used to repetitively charge the primary energy store is presented. Data obtained under rep-rate operation are shown to illustrate repeatability of the self break voltage and the subsequent output voltage pulse of the transformer.
  • Keywords
    power capacitors; power supplies to apparatus; power transformers; pulse generators; pulse transformers; pulsed power switches; spark gaps; 17.6 nF; 2 kHz; 30 kV; 350 kV; 40 pF; SF/sub 6/; dual resonant power transformer; high pressure SF/sub 6/ environment; peak repetition rate; power capacitor energy store; primary energy store; pulse forming line; pulsed power supplies; self-break high-pressure hydrogen spark gap switch; Assembly; Capacitance; Capacitors; Conductors; Hydrogen; Inductance; Oil insulation; Pulse transformers; Resonance; Switches;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Conference, 1995. Digest of Technical Papers., Tenth IEEE International
  • Conference_Location
    Albuquerque, NM, USA
  • Print_ISBN
    0-7803-2791-8
  • Type

    conf

  • DOI
    10.1109/PPC.1995.599824
  • Filename