Title :
Calibration comparison for vector network analyzers with switching errors
Author_Institution :
Div. of Electromagn. Fields, Nat. Inst. of Stand. & Technol., Boulder, CO, USA
Abstract :
Summary form only given, as follows. This paper demonstrates a method for comparing vector network analyzer calibrations in which each parameter in the error model, including the switch terms, may vary. This extends earlier calibration comparison methods that assume the switch terms to be fixed. The method is therefore applicable even to common methods that do not measure the switch terms directly and may therefore determine them erroneously.
Keywords :
S-parameters; calibration; measurement errors; network analysers; calibration comparison; error model; scattering parameters; switching errors; upper bound; vector network analyzers; Calibration; Electromagnetic analysis; Electromagnetic fields; Electromagnetic modeling; Error analysis; NIST; Postal services; Radio frequency; Scattering parameters; Switches;
Conference_Titel :
Precision Electromagnetic Measurements Digest, 1998 Conference on
Conference_Location :
Washington, DC, USA
Print_ISBN :
0-7803-5018-9
DOI :
10.1109/CPEM.1998.700020