• DocumentCode
    2965271
  • Title

    Experimental determination of the parameters for a salient rotor synchronous machine with and without pole screens

  • Author

    Danielsson, Christer ; Sadarangani, Chandur

  • Author_Institution
    ABB Corp. Res., Vasteras
  • fYear
    2008
  • fDate
    6-9 Sept. 2008
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    This paper investigates simulation models for salient pole solid rotor synchronous machines through experimental model identification. Two different methods are used, the classical stand-still frequency response test method and the more recent prediction error method. The results are compared and analyzed. It is shown that a third order model is required to describe the machine dynamics accurately. Further, the impact of extra copper pole screen is investigated, and it is concluded that these could have a beneficial effect with inverter supply.
  • Keywords
    frequency response; machine theory; rotors; synchronous machines; copper pole screen; machine dynamics; prediction error method; salient pole solid rotor; salient rotor synchronous machine; stand-still frequency response test; Circuit simulation; Damping; Equivalent circuits; Frequency response; Inverters; Solid modeling; Synchronous machines; System identification; Testing; Time measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines, 2008. ICEM 2008. 18th International Conference on
  • Conference_Location
    Vilamoura
  • Print_ISBN
    978-1-4244-1735-3
  • Electronic_ISBN
    978-1-4244-1736-0
  • Type

    conf

  • DOI
    10.1109/ICELMACH.2008.4799833
  • Filename