DocumentCode
2968682
Title
Diagnosis of induction motor faults using instantaneous frequency signature analysis
Author
Lebaroud, A. ; Clerc, G.
Author_Institution
LEC, Univ. de Constantine, Constantine
fYear
2008
fDate
6-9 Sept. 2008
Firstpage
1
Lastpage
5
Abstract
This paper investigates a new technique for diagnosing faults in three-phase induction motors. The instantaneous frequency signature analysis (IFSA) relates to the monitoring of the fundamental frequency modulation for the diagnosis of faults. The rotor and stator faults in induction machines involve an internal magnetic imbalance, which is reflected in the stator current. This effect may be detected by estimating the fundamental instantaneous frequency signature via stator current. The IFSA is a non-intrusive, on-line monitoring technique for the faults diagnosis.
Keywords
condition monitoring; fault diagnosis; frequency modulation; induction motors; rotors; stators; frequency modulation; induction motor faults; instantaneous frequency signature analysis; internal magnetic imbalance; online monitoring; rotor faults; stator current; stator faults; Coils; Condition monitoring; Fault diagnosis; Frequency; Induction motors; Magnetic analysis; Rotors; Shafts; Stator cores; Stator windings; Faults; Induction Motor; Instantaneous frequency signature analysis;