DocumentCode :
2968752
Title :
Use of Electro-Magnetic Analysis to monitor activity of a digital circuit in a non-intrusive way
Author :
Thomas, Sébastien ; Faura, David ; Duc, Guillaume ; Danger, Jean-Luc ; Regis, Didier ; Gatti, Marc
Author_Institution :
Thales Avionics, Meudon-La-Foret, France
fYear :
2011
fDate :
28-31 Oct. 2011
Firstpage :
1661
Lastpage :
1664
Abstract :
In this paper we introduce a fully non intrusive test method which is based on the Differential Electro-Magnetic Analysis (EMA). Our objective is to demonstrate the capability of this new method to detect a modification in a circuit, like a fault voluntary injected would be. This detection is carried out by comparing a reference trace, called Reference Signature, with a differential trace representing the observed electro-magnetic activity, called Control Signature. The results show the efficiency of the proposed method. We will then introduce the possibility offered by EM measurement to be used to detect a degradation of physical parameters on Avionics equipments where no intrusion is allowed.
Keywords :
avionics; digital circuits; fault diagnosis; Avionics; EM measurement; EMA; control signature; digital circuit; electro-magnetic analysis; fault voluntary; nonintrusive way; Aerospace electronics; Circuit faults; Databases; Degradation; Electromagnetics; Field programmable gate arrays; Reliability;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Sensors, 2011 IEEE
Conference_Location :
Limerick
ISSN :
1930-0395
Print_ISBN :
978-1-4244-9290-9
Type :
conf
DOI :
10.1109/ICSENS.2011.6127116
Filename :
6127116
Link To Document :
بازگشت