DocumentCode
2973794
Title
Scalloped electrodes for highly sensitive electrical measurements
Author
Vazquez, P. ; Dimaki, M. ; Svendsen, W.E.
Author_Institution
DTU Nanotech, Lyngby, Denmark
fYear
2011
fDate
28-31 Oct. 2011
Firstpage
1584
Lastpage
1587
Abstract
In this work we introduce a novel out-of-plane electrode with pronounced scalloped surface and high aspect ratio for electrical recordings of brain tissue in vitro, with the aim to reduce significantly the impedance of the measuring system. The profile and height of the structures is tailored by means of silicon fabrication techniques that sharpen them progressively and in a controlled manner. We will show that the use of the scalloped area achieves a great decrease in impedance, which is very significant for a reduction of noise in electrical measurements. The measured impedance reflects an important improvement in comparison with already available systems. Additionally, first test of durability prove the robustness of these needle-like electrodes during indentation motions. In conclusion, the resulting electrodes are robust, sharp structures that decrease the typical impedance of microelectrodes and are potentially suited for indentation and recording of brain tissue.
Keywords
bioelectric potentials; biomedical electrodes; brain; microelectrodes; brain tissue; electrical recordings; highly sensitive electrical measurements; microelectrodes; needle like electrode; out-of-plane electrode; scalloped electrodes; scalloped surface; Brain; Electrodes; Impedance; Impedance measurement; In vitro; Materials; Surface impedance;
fLanguage
English
Publisher
ieee
Conference_Titel
Sensors, 2011 IEEE
Conference_Location
Limerick
ISSN
1930-0395
Print_ISBN
978-1-4244-9290-9
Type
conf
DOI
10.1109/ICSENS.2011.6127359
Filename
6127359
Link To Document