• DocumentCode
    2974592
  • Title

    A coupled-circuit model for a DFIG operating under unbalanced conditions

  • Author

    Djurovic, S. ; Williamson, S.

  • Author_Institution
    Sch. of Electr. & Electron. Eng., Univ. of Manchester, Manchester
  • fYear
    2008
  • fDate
    6-9 Sept. 2008
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    The paper describes a time-stepped coupled-circuit model for a doubly-fed induction generator. The model, which is based on the summation of the harmonic winding inductances, is capable of representing both open- and short-circuit stator and rotor winding faults. The main purpose of this paper is to present evidence of the validity of this versatile and powerful technique and the advantages it offers when used for modeling and analysis of doubly-fed induction generator operation in unbalanced conditions.
  • Keywords
    asynchronous generators; rotors; stators; windings; DFIG; doubly-fed induction generator; harmonic winding inductances; open-circuit stator; rotor winding faults; short-circuit stator; time-stepped coupled-circuit model; Character generation; Circuit faults; Coupling circuits; Frequency; Induction generators; Power generation; Rotors; Stator windings; Wind energy generation; Wind power generation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines, 2008. ICEM 2008. 18th International Conference on
  • Conference_Location
    Vilamoura
  • Print_ISBN
    978-1-4244-1735-3
  • Electronic_ISBN
    978-1-4244-1736-0
  • Type

    conf

  • DOI
    10.1109/ICELMACH.2008.4800262
  • Filename
    4800262