DocumentCode
2974592
Title
A coupled-circuit model for a DFIG operating under unbalanced conditions
Author
Djurovic, S. ; Williamson, S.
Author_Institution
Sch. of Electr. & Electron. Eng., Univ. of Manchester, Manchester
fYear
2008
fDate
6-9 Sept. 2008
Firstpage
1
Lastpage
6
Abstract
The paper describes a time-stepped coupled-circuit model for a doubly-fed induction generator. The model, which is based on the summation of the harmonic winding inductances, is capable of representing both open- and short-circuit stator and rotor winding faults. The main purpose of this paper is to present evidence of the validity of this versatile and powerful technique and the advantages it offers when used for modeling and analysis of doubly-fed induction generator operation in unbalanced conditions.
Keywords
asynchronous generators; rotors; stators; windings; DFIG; doubly-fed induction generator; harmonic winding inductances; open-circuit stator; rotor winding faults; short-circuit stator; time-stepped coupled-circuit model; Character generation; Circuit faults; Coupling circuits; Frequency; Induction generators; Power generation; Rotors; Stator windings; Wind energy generation; Wind power generation;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Machines, 2008. ICEM 2008. 18th International Conference on
Conference_Location
Vilamoura
Print_ISBN
978-1-4244-1735-3
Electronic_ISBN
978-1-4244-1736-0
Type
conf
DOI
10.1109/ICELMACH.2008.4800262